QUESTIONAccording to the handbook, what may happen if a flared tube fitting is overtightened during installation?
- AThe tube flare may be badly damaged or completely cut off
- BThe line may blow out of the assembly under system pressure
- CThe seal improves because the flare is compressed more tightly
Show the answer and explanation
Correct answer: A. The tube flare may be badly damaged or completely cut off
- A — correct The handbook states that overtightening a fitting may badly damage or completely cut off the tube flare, or ruin the sleeve or fitting nut, which is why torque wrenches and prescribed torque values are used.
- B — incorrect Blowing out of the assembly or leaking under pressure is the consequence the handbook gives for failing to tighten sufficiently, not for overtightening.
- C — incorrect Extra torque does not improve the seal; the metal-to-metal contact is produced by a correctly formed flare tightened to the proper torque, and overtightening damages it.