QUESTIONA small aircraft has one generator rated at 60 amperes output, with no placards or load monitoring devices installed. Following the handbook guideline for keeping the battery charged in flight, what is the approximate acceptable total continuous connected electrical load?
- A48 amperes
- B54 amperes, or 90 percent
- C60 amperes, the full rating
Show the answer and explanation
Correct answer: A. 48 amperes
- A — correct Where placards or monitoring devices are not practical, the total continuous connected load may be held to approximately 80 percent of rated generator output capacity, and 80 percent of 60 amperes is 48 amperes.
- B — incorrect The guideline figure is 80 percent of rated output, not 90 percent, so this leaves too little margin for charging the battery in flight.
- C — incorrect Loading a generator to its full rated output leaves nothing to charge the battery, which is why the guideline holds the continuous load below the rating.